LX Fronius Compatible™ Owner's Manual - Page 2

Coolant Connections

If so equipped, the ends of the coolant hose push over a barbed fitting on

the end of the gun body and are secured by twisting the hose retainer to the

end of the hose. The hose retainer is re-usable and can be removed and

re-installed as needed.
The BLUE coolant supply hose pushes over a barbed fitting on the end of

the gun body and is secured by twisting the hose retainer to the end of the

hose. The hose retainer is re-usable and can be removed and re-installed as

needed.The opposite end of the BLUE hose pushes into a threaded coolant

fitting.
The RED coolant return hose pushes over the barbed fitting in the Power

Manifold. The opposite end of the RED hose pushes into a threaded return

hose of the coolant recirculator.
Both threaded fittings on the end of the BLUE and RED hoses are quick

connect fittings. MK Products compatible guns have interchangeable fittings,

so you can match as needed for your cooler. Both types of fittings require a

hose retainer.

Control Cable

A multi-conductor control cable is used on the Python LX

Fronius

Compatible

gun. The gun end of the cable is secured with a cable clamp and

the wires are connected to the potentiometer, micro switch, motor and the

gun body mechanically. Slack is left in the electric cable as it exits the back

of the gun to prevent cable and/or wire breakage. The cabinet end of the

control cable uses a 9-Pin, rectangular connector.

Section B

Operation

General

The Python LX

Fronius Compatible gun maintains a constant, steady,

uniform wire feed speed, regardless of curved or looped wire conduit. The

constant push exerted by the slave motor in the cabinet, combined with the

pull of the gun motor, causes the wire to literally float friction-free through

the wire conduit. The 24VDC gun motor is

controlled by a three and three-quarter (3-3/4) turn

potentiometer in the gun handle.

Controls and Settings

Potentiometer

The laterally-positioned potentiometer is located

in the lower end of the handle, providing up to 800

ipm with 3-3/4 turns.

Micro Switch

The micro switch assembly consists of the micro

switch, and leads.

Trigger Sensitivity

The amount of trigger lever travel can be

shortened for a quicker or more responsive action.
A more sensitive trigger lever is produced by

reducing the gap between the trigger lever and the

431-1898

5/16” Hose Retainer

431-1910

Quick Connect Fitting

431-1893*

Nipple

753-3379*

Left-Hand Threaded Fitting

*Must be ordered together

Trigger Sensitivity Adjustment

Screw Location

Screw adjusted out of trigger,

pre-setting the micro-switch

lever for shorter motion

sensitivity.