Python

®

LX Owner's Manual - Page 2

Gas Hose

The gas hose is pushed over a barbed fitting on the end of the gun body and

secured by twisting the hose retainer to the end of the hose (shown below).

The hose retainer is re-usable and can be removed and re-installed as

needed. The cabinet end of the gas hose uses our standard gas fitting (1/8” -

27 nps).

Water Hose

If so equipped; one end of the water hose is is pushed over a barbed fitting

and secured by twisting the hose retainer to the end of the hose. The hose

retainer is re-usable and can be removed and re-installed as needed. The

other end is connected to the center fitting on the power block.

Control Cable

A multi-conductor control cable is used on the Python LX gun. The gun end

of the cable is secured with a cable clamp and the wires are connected to the

potentiometer, the micro switch, the motor and the gun body mechanically.

Slack is left in the electric cable as it exits the back of the gun to prevent

cable and/or wire breakage. The cabinet end has a seven pin "W" clocked

amphenol connector.

Section B

Operation

General

The Python

LX gun maintains a constant, steady, uniform wire feed speed,

regardless of curved or looped wire conduit. The constant push exerted

by the slave motor in the cabinet, combined with the pull of the gun motor,

causes the wire to literally float friction-free through the wire conduit. The

24VDC gun motor is controlled by a three and three-quarter (3-3/4) turn

potentiometer in the gun handle.

Controls and Settings

Potentiometer

The laterally-positioned potentiometer is located in the lower end of the

handle, providing up to 800 ipm with 3-3/4 turns.

Micro Switch

The micro switch assembly consists of the micro switch, and leads.

Trigger Sensitivity

The amount of trigger lever travel can be shortened

for a quicker or more responsive action.
A more sensitive trigger lever is produced by

reducing the gap between the trigger lever and the

micro switch lever. By turning-in the trigger sensitivity

adjustment screw, it closed the gap between the

trigger lever and the micro switch lever.
This will enable the operator to increase the

sensitivity of the trigger lever.

Sensitivity Adjustment

With the wire feeder turned on (with or without

welding wire loaded), turn the screw in until the

micro-switch is activated. Once activated, the torch

and wire feeder motors will begin feeding wire.

Retract the screw accordingly until the system is

deactivated and adjusted to the operators' liking.

Trigger Sensitivity Adjustment

Screw Location

Screw adjusted out of trigger,

pre-setting the micro-switch

lever for shorter motion

sensitivty.