Troubleshooting guide – Dimplex EF3003 User Manual
Page 2
EF3003, SF3003, DF3003
TROUBLESHOOTING
GUIDE
GENERAL
Problem
Cause
Solution
Service Manual
Reference
Circuit breaker trips
or fuse blows when
unit is turned on
Improper circuit current rating
Additional appliances may
exceed the current rating of
the circuit breaker or fuse.
Plug unit into another outlet
or install unit on a dedicated
15 amp circuit
Remote control has a similar
frequency to other remotes in
the area
Unit turns on or off
by itself
Radio frequency disturbance
from outside sources
Select alternative frequency
code
Page 2
Lights dim in room
while the unit is on
Unit is drawing close to circuit
current rating
Move the unit to another
outlet or install unit on a
dedicated 15 amp circuit
Normal operation
The power cord may get
slightly warm to the touch
when the heater is on
Power cord gets
warm
Defective power cord
Replace power cord
Page 20
APPEARANCE
Problem
Cause
Solution
Service Manual
Reference
Improper operation
Refer to User’s Guide
Defective main on/off switch
Replace main on/off switch
Page 12
Defective remote control
Install new batteries into the
handheld transmitter /
reinitialize
Page 1
Fireplace does not
turn on
Loose wiring
Check wiring connections
Page 9
Defective flame motor
Replace flame motor
Page 15
Flame frozen
Loose wiring
Check wiring connections
Page 9
Burnt light bulbs
Replace light bulbs
Page 10
Loose wiring
Check wiring connections
Page 9
Flame not bright or
flame not visible
Defective light harness
Replace light harness
Log set dim, ember
bed not glowing
Burnt light bulbs
Replace light bulbs
Page 10
Flame Shutter
Defective flame motor
Replace flame motor
Page 15