Technical Specifications
Type
Modular Access & xWDM System for 19“ rack installation
Dimensions
MS416001M (3 HU)
450 x 130 x 250 mm (w x h x d)
84 TE with 3 HU modules
MS416010M (4 HU)
450 x 174 x 400 mm (w x h x d)
168 TE (1x84 TE front and 1x84 TE back) with 3 HU modules
MS416006M / MS416007M (1 HU)
450 x 43 x 285 mm (w x h x d)
3x 6 TE with 1 HU
Power Supply
Power Supply Module 230 V/ 50 Hz,
also for redundancy, optional with 48 V DC und 24 V DC
(not for MS416006/MS416007, integrated there)
Operating temp.
0°C to 55°C
Storage temp.
-20°C to 80°C
Rel. humidity
5% to 80% non condensing
Combinations
The 19” chassis (MS416001M) can take with one power supply (MS416004M) inserted
up to 12 modules. The power supply can be also be inserted redundant (2x
MS416004M), in that case there are 10 slots available for modules. For the power
redundancy it is also possible to combine 230 V AC and 24/48 V DC power supplies
together.
In the extended version (MS416010M, 4 HU) there are 14 slots on the front and 14 slots
on the back side available (total 28 slots). For the airflow it is necessary in insert min
two fan units (3 slot wide). So in combination with two power supplies and one
management modules it is possible to insert up to 17 modules. This 4 HU chassis is
optimised for the air flow and has larger insertion depth.
Furthermore there are smaller chassis for up to 3 modules available (MS416006M). this
chassis has a fixed integrated power supply and can be also delivered with a second
redundant power supply (MS416007M).
Additional there are deskt6op chassis with one and two slots available. Here the power
supply can be done either with an integrated or an external power supply. An optional
wall mount bracket is also available.