Rotary encoder installation – MicroE 1000 Mercury User Manual
Page 8
Installation Instructions
Rotary Encoders
Attach your hub/scale
assembly to the rotary
device. Refer to the
interface drawing. The
reflective surface of the
scale must face the sensor.
1
Page 6
3
Be sure the source power is off
before connecting the
SmartPrecision
TM
Alignment Tool.
Connect the M1000 encoder to the
SmartPrecision
TM
Alignment Tool.
2
4
Connect the Alignment Tool to the
Computer Interface Adapter.
Install the sensor on your mounting surface
referencing the appropriate datum surface as
shown on the interface drawing. Use 2 washers
per mounting screw.
Benching pins may be used to locate the sensor
if the system mechanical tolerances are adequate.
See data sheet for alignment tolerances, or keep
mounting screws loose for sensor alignment if
benching pins are not used.
To M1000 encoder
To Power Supply