96 Load keypad queuing number
0 Disable keypad queuing
1 Print first label then queue for remainder
2
3 Disable keypad pause
4 Queue for first label only
5 Queue for all labels
6
7 Queue for first label and disable keypad pause
98 Load labels taken sensor and external print switch control
LTS = Labels Taken Sensor
EPS = External Print Switch
0 Disable LTS Disable EPS
1 Enable LTS Disable EPS
2 Disable LTS Enable EPS
3 Enable LTS Enable EPS
2.6 ^E ENQUIRY MODE
The printer can be polled to acquire the state of the machine. When
an enquiry character (^E) is sent to the printer it will respond with
one of the following control characters:
SUB ^Z >RESTARTED<
Response to the first ENQ after power-up. This informs
the controlling unit that the printer has just powered
up and any previous set-ups are lost.
NAK ^U >DATA ERROR<
A data error has occurred (e.g. parity or barcode
error). This error condition is cleared when a print
cycle is started or when STX is received.
EM ^Y >LOW STOCK<
End of label stock. This error blocks the printing,
but a blank label may be feed out with the FF control
character. The error flag is cleared when a label has
been successfully fed out.
SYN ^V >TAKE LABEL<
Previous label not taken. This can only occur on
printers equipped with the label sensor option.
ACK ^F >READY<
Ready or no errors.