Microcom 450 User Manual
Page 11

25 MSI 2
26 MSI 3
28 MSI Human readable type 1
29 MSI Human readable type 2
32 UPCA human readable w/extended bars
33 UPCA human readable w/extended bars, no checksum
40 Code 128
42 Codabar
CGN CHARACTER GENERATOR NUMBER
This element determines which character generator to use.
Barcode and text character generators are stored in EPROM
memory. The number of character generators that can be stored
in the printers memory is limited by the size of the
generators.
FO FIELD ORIENTATION
This element determines the orientation of each field on the
label.
0 Horizontal normal orientation
1 Horizontal upsidedown orientation
2 Vertical right orientation
3 Vertical left orientation
4 Fixed width horizontal normal orientation
5 Fixed width horizontal upsidedown orientation
8 Fast fixed width horizontal normal orientation
9 Fast fixed width horizontal upsidedown orientation
FJ FIELD JUSTIFICATION
This element determines the justification of each field on the
label. Each field is justified relative to its orientation.
0 Left justified above base line
1 Right justified above base line
2 Left justified below base line
3 Right justified below base line
4 Centered above base line
5 Centered below base line
CMX CHARACTER MULTIPLIER X DIRECTION
This element multiplies each character in the Y direction. If
this element is not used, the default value of one will be
used. This element is only used by the M450 printer, all
others should use the default value.
CMY CHARACTER MULTIPLIER Y DIRECTION
This element multiplies each character in the Y direction. If
this element is not used, the default value of one will be
used.