INStALLAtION

WARNING: Make sure the

selector switch is in the OFF po-

sition before installing heater.

WARNING: Before installing in

a solid fuel burning fireplace, the

chimney flue and firebox must be

cleaned of soot, creosote, ashes

and loose paint by a qualified chim-

ney cleaner. Creosote will ignite

if highly heated. A dirty chimney

flue may create and distribute soot

within the house. Inspect chimney

and firebox flue for damage. If

damaged, repair flue and firebox

before operating heater.

WARNING: Installation, ser-

vice and repair of this appliance

must be performed by a qualified

installer, service agency, compa-

ny or gas supplier experienced

with this type of gas appliance.

Only factory authorized compo-

nents listed in these instructions

may be used in accordance with

manufacturer’s instructions and

all codes and requirements of

the authority having jurisdiction.

Any modifications to this kit,

or use of unauthorized compo-

nents or accessory items will

void manufacturer’s warranty

and may result in a hazardous

condition.

INSTALLATION AND CLEARANCES

Figure 2 shows technical information regarding

installation of your gas log set. Please make sure

all specifications shown are applicable before

installation is attempted.

Flue Opening Specifications
Note:

This vented appliance must be installed

only in a solid-fuel burning or UL127 factory-

built fireplace with a working flue and constructed

of noncombustible material. The fireplace must

include a working flue and venting system with

minimum openings shown in Figure 3.

LOG SIZING REQUIREMENTS

Min.

Flue

Size

Minimum Firebox Size

Log

Size Height Depth

Front

Width

Rear*

Width

18"

17"

14"

24"

20"

8"

24"

17"

14"

28"

22"

8"

*Measured at 14" depth.

SPECIFICATIONS (W.C.)

FUEL INLET

PRESSURE

MANIFOLD

PRESSURE

Min.

Max.

NG

7"

10.5"

3.5"

LP

11"

14"

10"

Figure 2 - Technical Information Chart

Figure 3 - Sizes and Clearances

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP)

for your unit. If your gas supply is not correct, do

not install heater. Call dealer where you bought

heater for proper type heater.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

vENTING SPECIFICATIONS FOR
INSTALLATION

The fireplace chimney flue and vent must be draft-

ing properly. To check vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of fireplace. Ob-

serve smoke and be sure vent is properly drawing

it up the chimney. If smoke spills out into the room,

extinguish flame and remove any obstruction until

proper venting is achieved.

The chimney flue damper must be fixed open to

provide a minimum of 43 square inches of free

air opening during operation of this log set. A

multipurpose damper clamp is provided to fix the

damper in position.