beautypg.com

Cleaning and maintenance, Specifications, Wiring diagram – Design Dynamics VTD-18N-PDG User Manual

Page 14

background image

www.desatech.com

111826-02J

14

CLEANING ANd

MAINtENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner and circulat-

ing air passageways of fireplace

clean. Inspect these areas of

fireplace before each use. Have

fireplace and chimney inspected

yearly by a qualified service per-

son. Fireplace may need more

frequent cleaning due to exces-

sive lint from carpeting, bedding

material, pet hair, etc.

Only limited cleaning will be required under normal

use of this appliance. Dust front grate and top of

receiver/valve. Do not use cleaning fluids to clean

logs or any other part of the appliance.

If after a period of use the flames start to exhibit

unusual shapes and behavior or burner fails to ignite

smoothly, burner holes may require cleaning. If this

happens, we recommend you contact your nearest

authorized service technician to get the appliance

serviced.

• Keep area around log set clean and clear of de-

bris.

• Periodically inspect burner for foreign matter

blocking air inlet and flame holes.

• Once every year a qualified agency or certified

chimney sweep should examine and clean venting

system of fireplace.

SPECIFICAtIONS

Models vTD-18N-PDG and vTD-18N-BTB

• Input Rating: 37,000/54,000 Btu/Hr

• Fuel: Natural Gas

• Ignition: Electronic

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

Max. - 10.5", Min. - 5.0*

• Shipping Weight: 32 lbs.
Models vTD-18P-PDG and vTD-18P-BTB

• Input Rating: 30,000/46,000 Btu/Hr

• Fuel: Propane/LP Gas

• Ignition: Electronic

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water):

Max.- 14", Min. - 11"*

• Shipping Weight: 32 lbs.
Models vTD-24N-PDG and vTD-24N-BTB

• Input Rating: 41,000/58,000 Btu/Hr

• Fuel: Natural Gas

• Ignition: Electronic

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

Max. - 10.5", Min. - 5.0*

• Shipping Weight: 34 lbs.
Models vTD-24P-PDG and vTD-24P-BTB

• Input Rating: 41,000/58,000 Btu/Hr

• Fuel: Propane/LP Gas

• Ignition: Electronic

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water):

Max.- 14", Min. - 11"*

• Shipping Weight: 34 lbs.

* For purpose of input adjustment

WIRING dIAGRAM

AUTO

OFF

ON

Thermopile