Technical specifications, Ce label – Meinberg NUC80E User Manual
Page 8
8
Technical Specifications
Display:
8-digit dot matrix display (5mm)
Interface:
20mA current loop input (passive)
Baudrate:
9600 baud
Framing:
7E2
Pulse Outputs:
shorted slave line detection and autotracking of the slave clocks
potential separation between power and control parts
pulse voltage: 24V
pulse current: 0.6A max.
pulse width:
1s (minute slave line), 0.5s (second slave line)
pulse outputs short circuit proof
Alarm Output:
Active when slave line is shortened or in case of driving failure
Connector:
Male connector, mixed F/H, DIN 41612
Type F: 24 poles, type H: 7 poles
Power
Requirements:
Input:
230V/50Hz
Output:
+5V/350mA (power supply for fhe radio clock)
Physical
Dimensions:
Eurocard, 100mm x 160mm, 1.5mm Epoxy
Front Panel:
Anodized aluminium, 60 mm wide
Ambient
Temperature:
0 ... 50°C
Humidity:
max. 85 %
CE Label
This device conforms to the directive 89/336/EWG on the
approximation of the laws of the Member States of the European
Community relating to electromagnetc compatibility.