Configuration of the board, Selecting the irig format – Meinberg TCR511 User Manual
Page 13
13
Configuration of the board
Configuration of the IRIG format to be used as well as the serial ports can be done by an
on board DIP-Switch.
Selecting the IRIG format
The IRIG or AFNOR format to be used can be selected by switches SW1-7 to SW1-10.
Please note that modulated and unmodulated code formats are applied to the board at
separate inputs.
Code
SW1-7
SW1-8
SW1-9
SW1-10
B122/B123
Off
Off
Off
Off
A132/A133
On
Off
Off
Off
B002/B003
Off
On
Off
Off
A002/A003
On
On
Off
Off
AFNOR NFS 87-500
Off
Off
On
Off
AFNOR NFS 87-500 ( DC )
On
Off
On
Off
The code AFNOR NFS 87-500 ( DC ) is the unmodulated version of the AFNOR code.
This unmodulated code is not standardized. The standard AFNOR-NFS 87-500 confi-
nes to the modulated signal.