beautypg.com

Bsl inputs, Installation, Power supply – Meinberg GPS162 User Manual

Page 10

background image

10

BSL inputs

Whenever the on-board software must be upgraded or modified, the new firmware
can be downloaded to the internal flash memory using the serial port COM0. There is
no need to insert a new EPROM.

The contacts of a key must be connected to the BSL inputs of GPS162. If this key is

pressed while the power supply of the module is switched on, a bootstrap-loader is
activated and waits for instructions from the serial port COM0. The new firmware
can be sent to GPS162 from any standard PC with serial interface. A loader program
will be shipped together with the file containing the image of the new firmware.

The contents of the program memory will not be modified until the loader program

has sent the command to erase the flash memory. So, if the BSL key is pressed
unintentionally, the firmware will not be changed accidentially. After the next
power-up, the system will be ready to operate again.

Installation

Power supply

The module GPS162 has two independent paths for connecting the power supply. The
main supply of +5 V must be connected to the contacts ‘VCC’ of the contact strip (see
pin assignments in ‘Technical specifications GPS162’). The supply for the master
oscillator (‘VDD’, +5V) is seperated from these contacts, because disturbing volta-
ges on the power lead could decrease the short term stability of the oscillator.

It is possible to use only one +5 V-output of a power supply for connecting the

receiver module and the oscillator. The ‘VCC’ and ‘VDD’ inputs should have
seperate leads from the power supply in this case. The contacts for the reference
potential are connected internaly. To achieve a good EMC-behaviour of GPS162 as
much ‘GND’ pins of the contact strip as possible should be connected to the ground
potential of the power supply directly.