Format of the computime time string, Technical specifications of antenna – Meinberg GPS161 User Manual
Page 24
24
Format of the Computime Time String
The Computime time string is a sequence of 24 ASCII characters starting with the T
character and ending with the LF (line feed, ASCII Code 0Ah) character. The format
is:
T:yy:mm:dd:ww:hh:mm:ss
The letters printed in italics are replaced by ASCII numbers whereas the other
characters are part of the time string. The groups of characters as defined below:
T
Start character
yy:mm:dd the current date:
yy
year of the century (00..99)
mm month
(01..12)
dd
day of month
(01..31)
ww
the day of the week
(01..07, 01 = monday)
hh:mm:ss the current time:
hh
hours
(00..23)
mm minutes
(00..59)
ss
seconds
(00..59, or 60 while leap second)
Carriage-return (ASCII code 0Dh)
Line-feed (ASCII code 0Ah)
See also other documents in the category Meinberg Hardware:
- SHSPZF LANTIME (153 pages)
- SHSPZF LANTIME (132 pages)
- GPS180 (68 pages)
- GPS167LCD-MP (48 pages)
- GPS164xHS (34 pages)
- GPS163TDHS (34 pages)
- DCF77C51 (20 pages)
- C28COM (22 pages)
- SyncBox PTPv2 (32 pages)
- DU70 (20 pages)
- UA509P (36 pages)
- VP100 20NET (25 pages)
- DU35S (18 pages)
- VP100 20 (22 pages)
- SDU (14 pages)
- FM614 (8 pages)
- RU226 (4 pages)
- GEN170TGP (30 pages)
- DCF77 PCI511 (22 pages)
- TCR167PCI (36 pages)
- TCR511PEX (20 pages)
- GPS169PCI (34 pages)
- DCF77 PC32E (22 pages)
- TCR510PCI (20 pages)
- USB 5131 (12 pages)
- TCR51USB (15 pages)
- GPS167PC (28 pages)
- PZF510 (26 pages)
- PZF511 (36 pages)
- PZF600 (40 pages)
- FDM509 (20 pages)
- FDM511 (26 pages)
- GPS162 (30 pages)
- TCR510 (28 pages)
- TCR509 (22 pages)
- TCG511 (22 pages)
- DCF77 UA509 (22 pages)
- VME31 (16 pages)
- UA32S (24 pages)
- NUC80E (20 pages)
- GPS L1 (3 pages)
- DOAL (10 pages)