FUNKUHREN

RU226

DCF77-receiver

Output signal

For evaluating of the DCF-time-telegramm, the module delivers the demodulated time marks.

The following values for the output signal are possible:

Positive pulses:
High-level

:

typ.: power supply - 1 V

Low-level

:

typ.: 0,1 V

Negative pulses:
High-level

:

typ.: power supply

Low-level

:

typ.: 0,1 V

With a +5V power supply, the output pulses are delivered with TTL-Level.

Pulse duration

The pulse duration of the output signal of RU226 depends on the conditions of receiption. The

resulting tolerances of the demodulated time marks have to be taken into consideration when
evaluating the DCF-telegramm. The following durations are possible:

DCF binary '0':

60ms

< t < 130ms

DCF binary '1':

150ms < t < 220ms

Power saving mode

By connecting an appropriate signal to the control pin "POFF", the module can be switched on or
off. The current consumption is reduced to about 1mA (with 5V power supply) in the power
saving mode. If this function is not used, the pin "POFF" may stay unconnected. The following
signals will cause the described mode:

POFF = GND or unconnected : module aktive
POFF = VDD

: module inaktive (power down mode)

Connections

The module is delivered with a four-wire cable of 1m length (others on request). The following
colours are corresponding to the described signals:

black

:

GND (reference potential)

red

:

VDD (power supply)

orange

:

DCF-MARK (demodulated time marks)

brown

:

POFF (power down input)