Special Inspections

Contents

3-1

Description ……………………………. 3-1

Storage/Winterization …………………. 3-1

DESCRIPTION

This section contains special inspection
requirements for a specific system after use, an
unusual event or storage.

STORAGE/WINTERIZATION


Entering
1. Remove any exterior dirt, grease and grime

that may trap moisture.

2. Flush all water suction and discharge tubes

(e.g. water pump,).

3. Ensure all water is drained from the tubes

and water pump.

4. Ensure all covers/caps for fluid reservoirs

are in proper operating condition and are
secured to the openings.

5. Fill Fuel tank to capacity, shut fuel shut off

valves at bottom of fuel tank.

6. Check tires for proper inflation.

7. Check Boom retaining hardware, ensure it

is operational and secure.

8. Lubricate all grease points (e.g. Hinge pins,

cylinder pins water pump suction bowl).

9. Check battery fluid level and charge.

10. Disconnect battery cables from battery.

11. Service all engine systems per CAT

SEBU7276-01 service manual.

12. If possible, shelter entire unit from the

elements.


Removing

1. Remove all covers and seals from all

fill/discharge openings and components.

2. Inspect piping for debris that may damage

unit that water will be pumped into.

3. Check to ensure all water pump reservoirs

are filled to the correct level and the fluid is
not contaminated.

4. Remove any exterior dirt, grease and grime

and treat any corrosion.

5. Service all Engine systems per CAT

SEBU7276-01 service manual.

6. Check all fluid levels for condition and

level, replace or adjust as necessary.

7. Check Braking system (if equipped) repair

as necessary.

8. Check safety chains for damage.

9. Check lighting system for proper operation,

repair as necessary.

10. Clean and connect battery cables to battery.

11. Perform ‘Daily’ maintenance checks, repair

as necessary.

12. Perform a full functional check of all MMP

control systems.