Special inspections – MEGA Corp. MMP4-5 User Manual
Page 16
MMP4-5
13 Feb 2012
SECTION 3
Special Inspections
Contents
3-1
Description ……………………………. 3-1
Storage/Winterization …………………. 3-1
DESCRIPTION
This section contains special inspection
requirements for a specific system after use, an
unusual event or storage.
STORAGE/WINTERIZATION
Entering
1. Remove any exterior dirt, grease and grime
that may trap moisture.
2. Flush all water suction and discharge tubes
(e.g. water pump,).
3. Ensure all water is drained from the tubes
and water pump.
4. Ensure all covers/caps for fluid reservoirs
are in proper operating condition and are
secured to the openings.
5. Fill Fuel tank to capacity, shut fuel shut off
valves at bottom of fuel tank.
6. Check tires for proper inflation.
7. Check Boom retaining hardware, ensure it
is operational and secure.
8. Lubricate all grease points (e.g. Hinge pins,
cylinder pins water pump suction bowl).
9. Check battery fluid level and charge.
10. Disconnect battery cables from battery.
11. Service all engine systems per CAT
SEBU7276-01 service manual.
12. If possible, shelter entire unit from the
elements.
Removing
1. Remove all covers and seals from all
fill/discharge openings and components.
2. Inspect piping for debris that may damage
unit that water will be pumped into.
3. Check to ensure all water pump reservoirs
are filled to the correct level and the fluid is
not contaminated.
4. Remove any exterior dirt, grease and grime
and treat any corrosion.
5. Service all Engine systems per CAT
SEBU7276-01 service manual.
6. Check all fluid levels for condition and
level, replace or adjust as necessary.
7. Check Braking system (if equipped) repair
as necessary.
8. Check safety chains for damage.
9. Check lighting system for proper operation,
repair as necessary.
10. Clean and connect battery cables to battery.
11. Perform ‘Daily’ maintenance checks, repair
as necessary.
12. Perform a full functional check of all MMP
control systems.