ELECTRICAL REQUIREMENTS AND SPECIFICATIONS
Power Requirement: 110/220V, 50-60 HZ, AC,
Circuit Protection:
3 AMP Circuit Breaker
NOTE: Older buildings, overloaded lines, and bad grounds can affect the operation of
your icreaseEXCEL. A dedicated line is best.
OPERATING SPEEDS
MODE
TRANSPORT SPEED
8.5x11 Sheet(est) 5 ½” Sheet(est)
(Feet per Sec.)
Perf Mode
2.5
12000
14000
Crease Mode
2.0
4500
5500
SPECIFICATIONS
Net Weight:
icreaseEXCEL……………………………………………..250 lbs
Overall Dimensions: …………………………………………………………………32”Lx27”Wx26”D
Min. Sheet Size:
………………………………………………………………..3”x5”
Max. Sheet Size:
…………………………………………………………………18”x20”-24”*
*NOTE: The icreaseEXCEL is capable of handling many types of applications above and
beyond the standard specifications. It is possible to feed quite a variety of jobs, from
30” sheets to die cut stocks. However, the performance of the icreaseEXCEL on these
special applications is directly related to the experience of the operator.
1a