beautypg.com

Venting installation instructions, Continued – Desa (V)VC36NE Series User Manual

Page 14

background image

www.desatech.com

116235-01G

14

VENTING INSTALLATION INSTRUCTIONS

Continued

Venting with Two 90° Elbows

Vertical (V) Horizontal (H

1

)

Horizontal (H

1

) +

Horizontal (H

2

)

5' min.

2' max.

6' max.

6' min.

4' max.

12' max.

7' min.

6' max.

18' max.

8' min.

8' max.

20' max.

20' max.

8' max.

20' max.

Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

45° Elbow

HORIZONTAL SYSTEM INSTALLATION
USING TWO 90° ELBOWS

The following configurations show the minimum

vertical rise requirements for a horizontal system

using two 90° elbows.

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H

1

) +

Horizontal (H

2

)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

20' max.

20' max.

Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

with Termination at 90° with Fireplace

45° Elbow