Location requirements, Installation clearances – Maytag MEDX6STBW Installation User Manual

Page 5

background image

5

You will need:

A location allowing for proper exhaust installation.

See “Venting Requirements.”

A separate 30 amp circuit.

If you are using power supply cord, a grounded electrical

outlet located within 2 ft. (610 mm) of either side of dryer.

See “Electrical Requirements.”

A sturdy floor to support the total weight (dryer and load)

of 200 lbs. (90.7 kg). The combined weight of a companion

appliance should also be considered.

Level floor with maximum slope of 1" (25 mm) under entire

dryer. (If slope is greater than 1" [25 mm], install Extended

Dryer Feet Kit, Part Number 279810.) If not level, clothes

may not tumble properly and automatic sensor cycles may

not operate correctly.

Do not operate your dryer at temperatures below 45°F (7°C). At

lower temperatures, the dryer might not shut off at the end of an

automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will

be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,

installation of the dryer in garages, closets, mobile homes, or

sleeping quarters. Contact your local building inspector.

Installation clearances:

The location must be large enough to allow the dryer door to

open fully.

Dryer Dimensions

Front View

Location Requirements

A

B

22

3

/

4

"

(578 mm)

27

3

/

4

"

(705 mm)

27

3

/

4

"

(705 mm)

13

3

/

4

"

(349 mm)

Side View

Back View

A. Wide opening side-swing door

B. Wide opening hamper door

*Most installations require a minimum 5½" (140 mm) clearance

behind the dryer for the exhaust vent with elbow. See “Venting

Requirements.”

Minimum spacing for recessed area or closet

installation

The dimensions shown following are for the minimum spacing

allowed.

Additional spacing should be considered for ease of

installation and servicing.

Additional clearances might be required for wall, door, and

floor moldings.

Additional spacing of 1" (25 mm) on all sides of the dryer

is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings

are acceptable.

Companion appliance spacing should also be considered.

29"

(737 mm)

43

3

/

8

"

(1102 mm)

1

/

2

"

(13 mm)

NOTE: Leveling legs should be 1/2" (13 mm) (to match height

of 3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height

of 3.8 cu. ft. capacity washer).

30

1

/

4

"

(768 mm)

14

1

/

2

"

(368 mm)

4

3

/

4

"

(121 mm)

4"

(101 mm)

14

1

/

2

"

(368 mm)

4

3

/

4

"

(121 mm)

Steam

Non-Steam