beautypg.com

Dakota Digital MULTI GAUGE UTV-1200 User Manual

Page 3

background image

page 3

MAN#650244:A

SPEED

Speed gauge menu

UNIT

Select unit for speed

Toggle between MPH and KPH (select unit to use for calibration)

AUTO

Auto calibrate speed to a marked mile or kilometer

Pulls up all values

 on speed and speed pulses in odometer

Press Right switch to finish cal and save value

ADJUST

Adjust speed cal while driving

ADJUST

Each press of left switch toggles direction of adjustment, right switch to save and exit

SRV MI (SRV KM)

Sets value of service odometer set when service odometer is reset

OFF ( OFF) Turns off the count down service odometer (default)

500 ( 800) Sets service to 500 mi or 800 km when resetting service odometer.

….

Service point can be set in 500 mi (800km) increments.

7500 (12000) Sets service to 7500 mi or 12000 km when resetting service odometer.

MAIN

Returns to info menu

TACH

Tachometer gauge menu

update

Sets update rate for tachometer readout screen

SLOW

tach updates at slowest rate (default)

MEDIUM

FAST

fastest update on tach

WARN

Sets RPM warning point (default 5500 RPM)

W 2250

Minimum warning point of 2250 RPM

….

Warning point can be set in 250 RPM increments

W 9750

Maximum warning point of 9750 RPM

SRV HR

Sets service hour value used when resetting count down service hour meter

OFF

Service hour meter disabled (default)

10

Minimum service hour set point

Service hour reset point can be set in 10 hr increments

310

Maximum service hour set point

MAIN

Returns to info menu

GAUGES

Gauge option menu

VLT HI

Set high voltage warning point (default 15.4V)

VLT LO

Set low voltage warning point (default 11.1 V)

OIL LO

Set low oil pressure warning point (default 9 PSI)

WTR HI

Set high water temp warning point and set temperature unit (default 251F)

DEG F (DEG C)

Select temp unit, press left switch to change, right switch to save

WTR HI

Select high warning, left switch to change, right switch to save

MAIN

Returns to info menu

OPTION

Option menu

DIM LV

Adjust dimming point on gauge

OFF

Dimming function is off

LVL 1

Gauge will dim when light on gauge face is very low (default)

7 selectable dimming levels

LVL 7

Gauge will dim early when more light is on gauge face

DM OUT

Enables/disables dim output for other gauges

ON

Dim output will be high when gauge is dimming

OFF

Dim output will be disabled (default)

WN OUT

Selects which gauges provide a warn out signal on warn out wire (default all on)

WN OUT

Gauges that provide signal out are lit up, left switch to change, right switch to save

NO WRN

Warn output wire is disabled

CLOCK±

Adjust clock speed for accuracy

-7 SEC

Subtract 7 seconds from clock every 24 hrs

0 SEC

No adjustment to factory clock speed (default)

+7 SEC

Add seven seconds to clock every 24 hrs

St odo

Allows presetting of odometer value on initial install (not available after 10 miles / 16km)

Set hr

Allows presetting of hour meter value on initial install (not available after 1.0 hrs)

MAIN

Returns to info menu

DONE

Leaves setup menu if selected