Installation and operating instructions – Louroe Electronics TLSP-PB-WF User Manual
Page 2
CONNECTING MODEL TLSP-PB TO A LOUROE BASE STATION
If TLSP-PB is to be connected to a Louroe Model DG-12II or DG-25III Alarming Base Station, please
refer to the installation instructions that accompany the DG12II or DG25III.
Microphone
Using shielded portion of recommended wiring:
1) RED wire goes to terminal A (12 Vdc supply)
2) BLACK wire goes to terminal B (audio output)
3) BARE wire (drain) goes to terminal C (ground)
The blank pin between terminal C and B is not used.
Speaker:
Mounted next to speaker is a 70V transformer with two lead wires WHITE and GREEN. Using wire nuts,
connect these two wires to the unshielded WHITE and GREEN cables of recommended wiring (West
Penn 356 or equivalent)
MICROPHONE AND SPEAKER
Located to the left of the PC Board and vertically positioned is a small terminal block
marked C, B, A. See drawing on Page 3.
Page 2 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
INSTALLATION AND OPERATING INSTRUCTIONS
tlsp_pb_inst_3/15
SPECIFICATIONS (Model TLSP-PB-WF and TLSP-PB-WS)
Output of microphone (Mic)
Frequency Response (Mic)
Current Drain (mic)
Speaker
Line Level (0 dB, 600
W
@ 1KW
)
40 Hz to 15 kHz
10 mA
3”, 2W w/ 70V transformer
Faceplate (TLSP-PB-WS)
Vandal Resistant
Stainless Steel
Faceplate (TLSP-PB-WF)
Backbox
Weight
Shipping Weight
6”L x 6”W
7”L x 7”W
6”H x 6”W x 4”D
4 lbs
7 lbs