Installation and operating instructions – Louroe Electronics LE-578 User Manual
Page 2
MICROPHONE CONNECTION:
If using West Penn 452 or equivalent with same color code, connect:
1. Red wire (12 Vdc) connects to terminal A of microphone terminal block
2. Black wire (audio out) connects to terminal B of microphone terminal block
3. Bare wire (ground) connects to terminal C of microphone terminal block
INSTALLATION TIP: If area to be monitored for audio is noisy or has background disturbances, the
microphone should be positioned close to the subject (4’ - 8’) if possible. Also, the microphone output can be
lowered by adjusting the gain control potentiometer. Rotating clockwise will increase the gain;
counterclockwise decreases the gain. The factory setting is 0dB output.
A represents +12 Vdc Power
B represents Audio Output
C represents Ground
A 3-pin terminal block is located on the back of the microphone housing, marked A, B, C.
CONNECTING VERIFACT D-AGC MICROPHONE TO A LOUROE™ BASE STATION OR AUDIO
INTERFACE ADAPTER
CONNECTING VERIFACT D-AGC MICROPHONE TO OTHER AUDIO DEVICES.
If a Louroe audio base station is not used and microphone is being connected directly to another receiver from
other manufacturers, 12 Vdc power must be applied to terminals A and C. (A is positive, C is negative).
Terminals B and C of microphone (C is common) go to the “Audio In” or “Line in” of the audio source. We
recommend shielded cable connections for terminal B and C (See last page for interconnection diagram)
INSTALLATION TIPS
1. Use 2 Cond 22AWG overall shielded audio cable only. West Penn 452, Belden 8451 or equivalent.
UNSHIELDED CABLE IS NOT SATISFACTORY FOR SOUND SYSTEMS.
2. When used at a cash register checkout, microphone should be installed closer to the customer rather than the cash
register, as the drawer sound could dominate the recording. It should be installed closest to the
area to be monitored and documented.
3. Avoid installing microphone near air vents, air conditioners, fans and other equipment that generate
high sound and air pressure.
4. If microphone is installed in a police interview room, room should be conditioned with any type of carpeting, acoustical
ceiling tiles, acoustical foam, etc. to reduce echo. This will enhance the quality of live and recorded audio.
5. The APR-1 and microphone should have a barrier or solid wall between them in order to avoid audio
feedback, especially when they are in close proximity to each other. If no barrier, microphone should be at least 25’
from APR-1 to avoid acoustical feedback.
All Louroe audio base stations and Interface Adapters have corresponding terminal blocks marked A, B, C.
Connect other end of cable as follows:
1. Red wire from microphone connects to pin A of Base Station (12Vdc)
2. Black wire from microphone connects to pin B of Base Station (Audio Output)
3. Bare wire from microphone connects to pin C of Base Station (Ground)
If base station is ALA-4/8 series, please refer to installation instructions for the specific model.
INSTALLATION AND OPERATING INSTRUCTIONS
Page 2 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
Verifact DGC microphone Is designed to be installed in a single gang electrical box for flush or surface mounting
to a wall or ceiling. It should be positioned 3 to 6 ft. from the area of desired coverage. Ceiling heights in excess of
10 ft. should be avoided.
MECHANICAL INSTALLATION:
Dgc_mic-inst_12/14
®
®
®