5 | mic paging – Lencore n.Form: MPI-6 User Manual
Page 10

section 2
2.5 | mic paging
8
1.
Connect a MIC to Lencore’s MIC pre-amp.
2.
Connect the audio output of the MIC pre-amp to one of the six audio inputs of the MPI.
3.
Connect the MIC switch wires to one of the six “Page on/off Inputs” terminal blocks.
Each terminal block will trigger a specific page zone as follows:
•
Input 1 = all-call
•
Input 2 = zone 251
•
Input 3 = zone 252
•
Input 4 = zone 253
•
Input 5 = zone 254
•
Input 6 = zone 255
4.
Press the MIC key and make the page.
Note: The zones must be configured with Lencore’s Sound Manager or Reports software (iNET only). For iNET, use
audio input 6 for MIC paging.
figure 3 - page on/off inputs