beautypg.com

Portable gasoline generators, Battery, Mounting battery to generator – Desa Hwi3000a User Manual

Page 8: Installing battery cables to engine

background image

8

118683

PORTABLE GASOLINE GENERATORS

R

Figure 10 - Battery Hold-Down System

(Model MGH6500AIE Shown)

TO STARTER

SOLENOID

TO ENGINE

BLOCK

120

ONLY

120

240V

ENM

000

0000

5

HOU

RS

1/10

FUL

L PO

WER

Figure 11 - Connecting Positive and

Negative Cables to Battery

(Model MGH6500AIE Shown)

MOUNTING BATTERY TO

GENERATOR

1. Secure battery to generator by battery

hold-down system. This system con-
sists of the battery mounting bracket,
hook bolts, and nut (see Figure 10).

2. Locate the red, positive (+) battery

cable from starter solenoid. Connect it
to the positive (+) battery terminal (see
Figure 11).

3. Locate the black, negative (–) battery

cable attached to engine block. Connect
it to the negative (–) battery terminal
(see Figure 11).

4. Check battery before starting engine.

Make sure fluid levels are full. Make
sure battery is charged.

See engine owner’s manual for more
information.

120

ONLY

120

240V

ENM

00000

005

HOU

RS

1/10

FULL PO

WER

Battery Mounting Bracket

Battery

Hook Bolt

Nut

Always wear safety glasses when working
with battery. Make sure battery terminals
are clean. Make sure cable connections
are tight.
Always shut down engine before removing
or attaching battery cables. Always remove
the negative (–) cable first. Always attach
negative (–) cable last.

INSTALLING BATTERY

CABLES TO ENGINE

1. Attach the red, positive (+) battery

cable to the starter solenoid on engine
(see Figure 8). This cable is factory
installed.

Starter

Solenoid

Figure 8 - Connecting Red, Positive (+)

Battery Cable to Engine Starter Solenoid

(Model MGH6500AIE Shown)

Figure 9 - Connecting Black, Negative

(-) Battery Cable to Engine Block (Model

MGH6500AIE Shown)

Red, Positive (+)

Battery Cable

Black,

Negative (–)

Battery Cable

CAUTION: Do not over tighten

positive terminal on starter so-

lenoid. Positive terminal could

rotate and cut into negative ter-

minal, causing a short.

IMPORTANT: Make sure battery connec-

tions are the correct polarity. Electric start
generators use negative ground, 12-volt DC
starting system.
Models MGH5000EIE and MGH6500AIE
have an electric starter. A battery is not
supplied with generator. You must provide
a 12-volt, 32-amp-hour battery. The positive
and negative battery cables are supplied
with generator. You must install these cables
before mounting battery.

CAUTION: If you remove bat-

tery, insulate the red, positive (+)

battery cable terminal. Insulate

with electrical tape. Exposed

terminal may spark when genera-

tor runs.

WARNING: Battery contains

sulfuric acid. Contact with skin

or eyes may cause severe burns.

Do not tilt generator with battery

installed. Tilting could cause bat-

tery acid to spill. Wear protective

clothing and face shield when

servicing. Keep out of children’s

reach.

• If battery acid gets on your skin,

wash with water.

• If battery acid gets in your eyes,

flush with water at least 15

minutes. Call a doctor at once.

Battery acid is poisonous.

• If swallowed, drink large amounts

of water or milk. Follow with milk

of magnesia or vegetable oil.

Call a doctor at once.

WARNING: Battery gives off

explosive gases. Keep sparks,

flames, and cigarettes away. Do

not remove or install battery

cables when engine is cranking

or running. Only service or use

battery in a well-vented area.

BATTERY

(Models MGH5000EIE and

MGH6500AIE)

2. Attach the black, negative (–) battery cable

to the engine block. Use the bolt, nut, and
two washers provided with the battery
cables. Use long mounting hole on oppo-
site side of engine from starter solenoid.
Attach cable as shown in Figure 9.

This manual is related to the following products: