PORTABLE GASOLINE GENERATORS

R

STORAGE

IMPORTANT: Keep generator level while in

storage. Never store generator upside down
or standing on end.
Note: We supply the engine owner’s manual

with generator. Refer to that manual for
questions concerning engine storage.
Use a fuel additive, such as STA-BIL

®

or an

equivalent, when storing generator with fuel
in fuel tank. This will minimize fuel gum
deposits from forming in engine.
Cover and store generator in a clean, dry
place. Do not expose generator to extreme
high or low temperatures during storage.

WARNING: The muffler be-

comes very hot during operation.

The muffler remains hot for a

while after shutdown. Let engine

cool before storing.

WARNING: Remove all fuel from

fuel tank before storing generator.

Store fuel in approved container.

Store fuel in a well-vented area free

of open flames or sparks.

MAINTENANCE

AND REPAIRS

WARNING: Only a qualified

electrical service person should

service and repair the alternator

on this generator. Use only factory

approved replacement parts.

STOPPING ENGINE

IMPORTANT: The engine speed is preset.

The throttle is locked in preset position. Do
not adjust throttle.
Follow the steps below to stop engine.
1. Remove all electrical loads from gen-

erator (see Disconnecting Electrical
Loads

). Remove electrical loads one

at a time.

2. Let engine run for two or three minutes

after removing electrical loads. This
lets engine cool slightly.

3. Turn engine switch to the OFF position

(see Figure 21).

4. Turn fuel valve lever off. Do this by

moving valve lever fully to the left (see
Figure 22).

HONDA

OFF

ON

START

ENGINE SW

CIRCUIT
BREAKER

ON/push OFF

Models MGH5000EIE

and MGH6500AIE

Figure 21 - Engine Switch In OFF Position

Figure 22 - Fuel Valve Lever Off (Model

MGH6500AIE Shown)

Fuel Valve Lever (Off Position)

OFF

ENGINE SW

ON

Models HWI3000A,

MGH3000GA, MGH3000A,

MGH4000D, MGH4000DI,

MGH5000E, and

MGH5000EI

OPERATION

Continued

IMPORTANT: Keep generator level when

servicing. Never turn generator upside down
or stand it on end to service.
Note: We supply the engine owner’s manual

with generator. Refer to that manual for
questions concerning engine maintenance
and repairs.
Non-engine parts require little maintenance.
Keep generator clean. Use a damp cloth to
clean outside surfaces. Never use water to
clean generator. Water can cause damage to
internal parts. Use vacuum to clean air inlet
and outlet louvers of alternator.

CAUTION: Shut off generator

before performing maintenance.

CAUTION: The engine speed

is preset. The throttle is locked

in preset position. Do not adjust

throttle. Preset position lets

engine run at 3600 RPM under

load. The engine must maintain

3600 RPM for generator to create

correct voltage. Running engine

at lower speeds will damage gen-

erator and powered items.