beautypg.com

Lacava llc 4 – Lacava 0614 User Manual

Page 4

background image

LACAVA LLC

4

Installation Instructions/Instrucciones de Instalación

1. Remove the plaster guard from the spout connection.

4. Determine the location of the valve. Make sure the center

of the valve will measure 1 1/8” - 1 3/4“ from the surface of

the finished wall. Then install supportive framing to mount

valve to.

5. Position the valve in the wall (check depth) and secure into

place on the support framing using the included screws.

6. Install 1/2”NPT threaded copper adapters to the hot & cold

inlets, applying teflon tape to all threaded connections.

Then solder copper piping onto adapters and run to

designated water supply or outlet.

Important! Take the following precautions if soldering copper

piping directly onto valve:

a) Remove ALL components from the valve prior to soldering,

including plaster guards & cartridges.

b) Wrap valve body with cold rag before soldering. Take

special care not to overheat brass rough-in.

c) Use copper piping only, do not attempt to solder steel

piping to valve.

d) Flush all pipes before reinstalling components

e) Reinstall all components after soldering.

2. Screw the brass spout connector into the rough-in assembly

until tight. It is recommended to wrap the threaded end with

Teflon tape prior to installing.

3. Place the plaster guard back into place on to the rough-in assembly,

over the now attached brass spout connector.

1 1/8” - 1 3/4”

H

C

This manual is related to the following products: