Installation Instructions/Instrucciones de Instalación
1. Determine the location of the valve and install support
framing.
2. Position the valve in the wall and secure into place on the
support framing using the provided screws. Refer to the
roughing-in dimensions on page 2 (or as marked on the
plaster guards) for additional mounting information.
3. Install 1/2”NPT threaded copper adapters to the hot & cold
inlets, applying teflon tape to all threaded connections.
Then solder copper piping onto adapters and run to
designated water supply or outlet.
Important! Take the following precautions if soldering copper
piping directly onto valve:
a) Remove ALL components from the valve prior to soldering,
including plaster guards & cartridges.
b) Wrap valve body with cold rag before soldering. Take
special care not to overheat brass rough-in.
c) Use copper piping only, do not attempt to solder steel
piping to valve.
d) Reinstall all components after soldering.
4. Make sure the cartridge is in the off position and then turn on
the hot and cold water supplies and check for any leaks.
5. Remove the plaster guards and set up a bucket below the
spout opening to collect water.
6. Slowly open the cartridge and allow the water to flow for a
minute.
7. Close the valve and check for any leaks. Repair if necessary.
8. Reattach the plaster guards to the rough-in and finish the
surrounding wall. To ensure proper fit, do not oversize the
holes for the spout and handle - use the plaster guards as a
guide for correct diameter.
9. Remove plaster guards once the finished wall is complete.