INSTALLATION WIRING DIAGRAM

Use 8 AWG

or larger on

Output & Gnd

L

N

R

INPUT

Chassis

Ground

NOTE: Minimum wire size on charger
output and ground is

For a length

of 10 feet or longer

is required.

Smaller gauge wire may cause overheating of

terminal. Use 2-966067 wire ferrule
over wire to simplify insertion of wire into
terminal strip and to improve connection.

Additional information is available upon request.

#8 AWG.

#6 AWG

Strip insulation to

11/16” and install
wire ferrule

supplied, 2 places

A.C. INPUT POWER

Optional -

80 Amp

Automatic Circuit Breaker

(part #: FUS-80-A)

GROUND

LINE

NEUTRAL

NOTE: Pin 1 of indicator must go to Pin 1
of Remote Display on charger.

Pin 2 of indicator must go to Pin 2
of Remote Display on charger, and so forth.

Check connections and color of wires
before plugging-in.

VEHICLE

BATTERY

COM

AUTO

PUMP

+ +

OUTPUT

AUTO

PUMP

AUTO CHARGE 1200

PUMP PLUS

Pressure

Switch

Auto Pump

Air Compressor

make sure

the Auto Pump

is mounted

vertical.

Note:

Range

Nut

BLK

BLK

RED
RED

BLACK

Chassis

Ground

WIRE SIZE CHART

CONNECTION

DEFINITION

WIRE SIZE

COM

VEHICLE

BATTERY

AUTO

PUMP

NEGATIVE CHARGING LEAD

POSITIVE CHARGING LEAD FOR BATTERY

POSITIVE OUTPUT FOR AUTO PUMP

8 AWG

8 AWG

14 AWG

INPUT

14 AWG