INSTALLATION WIRING DIAGRAM
Use 8 AWG
or larger on
Output & Gnd
L
N
R
INPUT
Chassis
Ground
NOTE: Minimum wire size on charger
output and ground is
For a length
of 10 feet or longer
is required.
Smaller gauge wire may cause overheating of
terminal. Use 2-966067 wire ferrule
over wire to simplify insertion of wire into
terminal strip and to improve connection.
Additional information is available upon request.
#8 AWG.
#6 AWG
Strip insulation to
11/16” and install
wire ferrule
supplied, 2 places
A.C. INPUT POWER
Optional -
80 Amp
Automatic Circuit Breaker
(part #: FUS-80-A)
GROUND
LINE
NEUTRAL
NOTE: Pin 1 of indicator must go to Pin 1
of Remote Display on charger.
Pin 2 of indicator must go to Pin 2
of Remote Display on charger, and so forth.
Check connections and color of wires
before plugging-in.
VEHICLE
BATTERY
COM
AUTO
PUMP
+ +
OUTPUT
AUTO
PUMP
AUTO CHARGE 1200
PUMP PLUS
Pressure
Switch
Auto Pump
Air Compressor
make sure
the Auto Pump
is mounted
vertical.
Note:
Range
Nut
BLK
BLK
RED
RED
BLACK
Chassis
Ground
WIRE SIZE CHART
CONNECTION
DEFINITION
WIRE SIZE
COM
VEHICLE
BATTERY
AUTO
PUMP
NEGATIVE CHARGING LEAD
POSITIVE CHARGING LEAD FOR BATTERY
POSITIVE OUTPUT FOR AUTO PUMP
8 AWG
8 AWG
14 AWG
INPUT
14 AWG