beautypg.com

Kussmaul Electronics 091-9-2000 User Manual

Page 3

background image

Battery Saver & Indicator

A 3 ampere BATTERY SAVER is built into the charger. When connected as

shown in the installation wiring diagram, loads on battery #1 such as radios and

rechargeable hand lights are automatically switched to the BATTERY SAVER

when power is applied to the charger. The BATTERY SAVER allows more efficient

charging by removing these loads. A BATTERY SAVER overload indicator alerts

the operator that the BATTERY SAVER load has exceeded 3 amperes.

WHEN A BATTERY SAVER OVERLOAD OCCURS:

a. Remove the loads for approximately two minutes

b. Reduce the load to 3 amperes or less

c. Reapply the load to the BATTERY SAVER

No fuses are required or provided as the BATTERY SAVER contains an electronic

overload interrupter.

Remote Dual Battery Charge Condition Indicator

This remote indicator shows the charge condition of each battery in 10 levels

from “LOW CHARGE” to “FULLY CHARGED”. This device indicates a defective

battery when a bar graph does not rise to the “FULLY CHARGED” level after an

extended period of charging.

NOTE: If a battery is being charged with an external load of 1.5 to 4 amperes

across it’s terminals, the bar graph may move down 1 or 2 levels. This

does not indicate a defective battery.

To avoid this, connect all external loads to the BATTERY SAVER

terminals.

Loads connected to the BATTERY SAVER will be powered either from

the BATTERY SAVER power supply when the A.C. power is “ON”, or

they will be connected to battery #1 when the A.C. power is “OFF”.