Kussmaul Electronics 091-22F-A User Manual
Auto current f-a, D.c. current sensor with aux. input, Kussmaul electronics co., inc
AUTO CURRENT F-A
D.C. CURRENT SENSOR WITH AUX. INPUT
INSTALLATION INSTRUCTIONS
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826
KUSSMAUL ELECTRONICS CO., INC.
170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
SCHEMATIC
The Auto Current F-A detects current and closes a
switch when the sensed current flows, to provide a
remote indication. An electronic frasher interrupts the
indicator output approximately once per second to
provide a flashing indication.
An Auxiliary input permits operating the flasher from
other grounding switches. Any number of switches
may be connected in parallel to terminal 4 to operate
the Indicator Lamp.
Warning Indicator is limited to 5 amperes maximum.
MODEL
NUMBER
ORDERING INFORMATION
RESIST
OHMS
MIN. OPER.
AMPS
MAX. OPER.
AMPS
SWITCH
RATING 12V
091-22F-A
091-22F-A-6
.01
.2
1.0
0.10
30
4
5 AMP
5 AMP
October 20, 2006
Chassis
Ground
Chassis
Ground
Chassis
Ground
Chassis
Ground
Indicator
Lamp
Door
switch
Door
switch
Loads
Loads
S2
G
D
IN
D
12
V
S1
Compartment
Lights
Chassis
Ground
Chassis
Ground
Auxiliary Input
Switch
AU
X
S1
S2
AUX
GD
+12V IND
TIMER
SWITCH
SENSOR
RE
L
A
Y