beautypg.com

Installation wiring diagram, Wire size chart, Auto charge 11 pim – Kussmaul Electronics 091-11PIM User Manual

Page 3

background image

INSTALLATION WIRING DIAGRAM

NOTE: Sense leads are shown con-
nected to battery #1 but may be
connected to either battery at the
installers option. The sense leads
however must be connected for the
charger to operate. The charger
does not require a 2 battery vehicle
to function properly. For single bat-
tery vehicles connect to battery #1.

IMPORTANT: Wire size is for a
maximum length of 20 feet. If wiring
is to be longer, larger wiring is re-
quired. Additional information is
available on request.

WIRE SIZE CHART

CONNECTION

ITEM

DEFINITION

WIRE

SIZE

COM

BATTERY

COMMON

NEGATIVE CHARGING LEAD
FOR BATTERIES

12

AWG

BAT 1

BATTERY

#1

POSITIVE CHARGING LEAD
FOR BATTERY # 1

12

AWG

BAT 2

BATTERY

#2

POSITIVE CHARGING LEAD
FOR BATTERY # 2

12

AWG

SENSE

_

NEGATIVE

SENSE

NEGATIVE VOLTAGE SENSE
LEAD. DETECTS VOLTAGE

16

AWG

SENSE

+

POSITIVE

SENSE

POSITIVE VOLTAGE SENSE
LEAD. DETECTS VOLTAGE

16

AWG

POS

BAT1

POWER

5 AMP

Chassis

Ground

BAT2

AUTO CHARGE 11 PIM

COM

IND

-

+

SENSE

Chassis
Ground

BA

TT

ER

Y

1

BA

TT

ER

Y

2