Drain condensate separator weekly, Vehicle tubing installation – Kussmaul Electronics 091-9HP User Manual
Page 4
VEHICLE TUBING INSTALLATION
1. Mount all components in a suitable location, preferably in a high area above the air system.
Do not mount in engine compartment or near any source of heat or dirt . The system may
be connected to any point in the vehicle's air system .
2. Mount air compressor in a vertical position as shown.
3.
CAUTION no condensate or water must be allowed to enter or accumulate in the output of
the Auto Pump . Route output pressure line downward from Auto Pump to permit moisture
to drain away .
Water in the pump outlet will induce failure .
DRAIN CONDENSATE SEPARATOR WEEKLY
4. All connections for air lines are 1/4" NPT . Use Teflon tape, or equivalent on all
connections to insure no leakage of air.
5. The recommended installation of the Auto Pump air compressor system is shown below.
6. Note that an external check valve is located between the compressor and the pressure
switch. No additional check valve is required.
7. Mount the air compressor. Connect a suitable piece of flexible tubing from the outlet port of
compressor to the air tank . (Tubing and connectors are not supplied.)
8. An optional Mounting Plate 091-9H-1 is available to reduce any vibration and noise from the
Auto Pump and to simplify pump mounting.
Auto Pump
Air Pressure System
Air Line
The Flow of
Any Moisture
1/4" NPT
Outlet Port
Truck
Body
Optional
Mounting
Plate kit
091-9H-1
Note: compressor must be mounted above
air tank to assure that moisture will flow