Wiring – Kussmaul Electronics 091-187-12 User Manual
Page 4
IV. LOCAL BATTERY CHARGE CONDITION INDICATOR
This indicator shows the charge condition of each battery in 10 levels from “LOW CHARGE” to
“FULLY CHARGED”. This device indicates a defective battery when a bar graph does not rise to
the “FULLY CHARGED” level after an extended period of charging.
NOTE: If a battery is being charged with an external load of 4 to 10 amperes across, the bar graph
may move down 1 or 2 levels. This does not indicate a defective battery.
VI. BATTERY SELECTOR SWITCH
Used to select between Lead-Acid or AGM batteries. The selector switch is factory set to Lead-Acid.
WIRING
I. BATTERY CHARGER WIRING INSTRUCTIONS
1. Refer to Installation Wiring Diagram I. and II.
2. Refer to Wiring Specifications to determine the recommended wire size and maximum lengths.
Using a smaller gauge may cause overheating of the terminal. Additional information is available
upon request if longer, larger wiring is required.
3. Make sure the position of the Battery Selector Switch matches the battery type. The switch is
factory to Lead-Acid. Switch to AGM when using AGM style batteries. Refer to Wiring Diagram
III.
4. Double check all wiring before applying AC power to input terminal.
5. Apply AC power (shoreline power) to input terminal and observe that the charger is operating.
6. Verify that the battery voltage appears at the charger output terminals. A minimum of 6 volts is
required to start the charger
II. WIRING SPECIFICATIONS
Length of Wire to Battery (feet)
0 - 5
< 5 - 10**
< 10 - 20*
Battery Charger Connections
V. BAT +
COM - V. BAT + COM - V. BAT + COM -
8
8
6
6
4
4
Wire Ferrule Used
091-TERFER812
091-TERFEB612
None
* Consult factory if length of wire to battery is longer than 20 feet
** Supplied with wire terminal hardware for 10 foot installation