beautypg.com

Installation wiring diagram – Kussmaul Electronics 091-168-12 User Manual

Page 5

background image

INSTALLATION WIRING DIAGRAM

IMPORTANT: Minimun wire size on charger output and ground is #6 AWG for a maximum
length of 25 feet. If wiring is to be longer, #4 AWG wire is required. Smaller gauge wire may
cause overheating of terminal. Additional information is available upon request.

NOTE: Use two(2) TERFEB612 Wire Ferrules over wire to simplify insertion of wire into
terminal strip and improve connection.

POWER

RESET

BATTERY CONNECTION

EQUALIZED

HI RESISTANCE

HI TEMPERATURE

HI VOLTAGE

LOW VOLTAGE

SHUTDOWN

CHARGER INOP.

FAN ON

REMOTE

FUSE

INPUT

L

N

AUTO CHARGE SD

AUTOMATIC BATTERY CHARGER

R

OUTPUT

+

1

2

3

4

5

+12V

GND

Volts

Amps

BAT

TER

Y

Black

White

Green

A.C. Input
Power

Strip insulation to
11/16” and install
wire ferrule
supplied, 2 places