Data safety, Afety – Dot Hill Systems SANnet II 200 User Manual
Page 27

No single-point-of-failure
Supported
Automatic engagement of replacement 
controller
Supported
Dynamic cache memory allocation
Supported 
Cache memory is dynamically allocated, not fixed.
Environment management
Supported 
SAF-TE, S.E.S., ISEMS (I
2
C interface), and onboard controller
voltage/temp monitor are all supported in both single and 
redundant controller mode. In the event of controller failure, 
services can be taken over by the existing controller.
Cache battery backup
Supported 
Battery backup solutions for cache memory are supported in both 
single controller and redundant modes.
Load sharing
Supported 
Workload can be flexibly divided between different controllers by 
assigning logical configurations of drives (LDs/LVs) to different 
controllers.
User-configurable channel mode
Supported 
Channel modes configurable (SCSI) as HOST or DRIVE in both 
single controller and redundant controller mode.
Redundant controller firmware upgrades
Supported 
Firmware upgrade can be downloaded to the primary controller 
and then be adopted by both controllers, without interrupting host 
I/O.
Redundant controller firmware 
synchronization
Supported 
In the event of controller failure, a replacement controller running 
a different version of firmware can restore a redundant array with 
a failed controller. Different firmware versions can be auto-
synchronized later.
Data Safety
Regenerate parity of logical drives
Supported 
Can be performed periodically by the user to ensure that bad 
sectors do not cause data loss in the event of drive failure.
Bad block auto-reassignment
Supported 
Automatic reassignment of bad block 
Battery backup for cache memory
Supported 
The battery backup solutions provide long-lasting battery support 
to the cache memory when power failure occurs. The unwritten 
data in the cache memory can be committed to drive media when 
power is restored.
Verification on normal writes
Supported 
Performs read-after-write during normal write processes to ensure 
data is properly written to drives.
Verification on rebuild writes
Supported 
Performs read-after-write during rebuild write to ensure data is 
properly written to drives.
Verification on LD initialization writes
Supported 
Performs read-after-write during logical drive initialization to 
ensure data is properly written to drives.
27