beautypg.com

Storing, transporting, or shipping, Preventative maintenance schedule – Desa B200 User Manual

Page 6

background image

6

102569

PORTABLE FORCED AIR HEATER

200,000 Btu/Hr

Item

How Often

How To

Fuel tank

Flush every 150-200 hours

See Storing, Transporting,

of operation or as needed

or Shipping

Air output and

Replace every 500 hours of

See Air Output, Air Intake,

lint filters

operation or once a year

and Lint Filters, page 8

Air intake filter

Wash and dry with soap and

See Air Output, Air Intake,

water every 500 hours of

and Lint Filters, page 8

operation or replace as needed

Fuel filter

Clean twice a heating season

See Fuel Filter, page 9

or replace as needed

Spark plug

Clean and regap every 600

See Spark Plug, page 10

hours operation or replace
as needed

Fan blades

Clean each season or as needed

See Fan, page 8

Motor

Not required/permanently lubricated

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

STORING,
TRANSPORTING,
OR SHIPPING

Note:

If shipping, transport companies re-

quire fuel tanks to be empty.

1.

Drain fuel tank.

Note:

This model has a drain plug on

underside of fuel tank. Remove drain
plug to drain all fuel. Be sure all fuel is
removed.

2.

Replace drain plug.

3.

If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.

4.

Replace fuel cap and drain plug. Prop-
erly dispose of old and dirty fuel. Check
with local automotive service stations
that recycle oil.

5.

If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.

IMPORTANT:

Do not store kerosene over

summer months for use during next heating
season. Using old fuel could damage heater.

PREVENTATIVE
MAINTENANCE
SCHEDULE