Storing, transporting, or shipping, Preventative maintenance schedule – Desa B200 User Manual
Page 6

6
102569
PORTABLE FORCED AIR HEATER
200,000 Btu/Hr
Item
How Often
How To
Fuel tank
Flush every 150-200 hours
See Storing, Transporting,
of operation or as needed
or Shipping
Air output and
Replace every 500 hours of
See Air Output, Air Intake,
lint filters
operation or once a year
and Lint Filters, page 8
Air intake filter
Wash and dry with soap and
See Air Output, Air Intake,
water every 500 hours of
and Lint Filters, page 8
operation or replace as needed
Fuel filter
Clean twice a heating season
See Fuel Filter, page 9
or replace as needed
Spark plug
Clean and regap every 600
See Spark Plug, page 10
hours operation or replace
as needed
Fan blades
Clean each season or as needed
See Fan, page 8
Motor
Not required/permanently lubricated
WARNING: Never service
heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.
STORING,
TRANSPORTING,
OR SHIPPING
Note:
If shipping, transport companies re-
quire fuel tanks to be empty.
1.
Drain fuel tank.
Note:
This model has a drain plug on
underside of fuel tank. Remove drain
plug to drain all fuel. Be sure all fuel is
removed.
2.
Replace drain plug.
3.
If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.
4.
Replace fuel cap and drain plug. Prop-
erly dispose of old and dirty fuel. Check
with local automotive service stations
that recycle oil.
5.
If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.
IMPORTANT:
Do not store kerosene over
summer months for use during next heating
season. Using old fuel could damage heater.
PREVENTATIVE
MAINTENANCE
SCHEDULE