The following minimum clearances from combustible materials must be
maintained when the appliance is in use:
top – 1000 mm, rear – 450 mm, sides – 250 mm.
Openings at the rear and sides of the appliance provide air for
combustion and must not be obstructed.
CLEARANCES
Height – hood closed 1235 mm, hood open 1605 mm
Width – 665 mm (without shelves)
Depth – hood closed 660 mm, hood open 715 mm
OVERALL DIMENSIONS
Appliance specifications can be found on the data label attached to the
side panel of the appliance body.
SPECIFICATIONS
Appliances for use with bottled gas are labelled ‘Universal LPG’ or
‘Propane’. Appliances for use with natural gas are labelled ‘Natural Gas’
and must be installed by an authorised person. Check the gas type sticker
attached to the appliance.
Your Outdoor Range barbecue is preset at the factory to operate on
bottled gas only, unless specified otherwise.
• FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN A
FIRE OR EXPLOSION WHICH COULD
CAUSE SERIOUS BODILY INJURY,
DEATH OR PROPERTY DAMAGE.
• ACCESSIBLE PARTS MAY BE
VERY HOT.
• KEEP YOUNG CHILDREN AWAY.
• ANY MODIFICATION OF THIS
APPLIANCE MAY BE DANGEROUS.
• DO NOT MOVE THIS APPLIANCE
DURING USE.
• TURN OFF THE GAS SUPPLY AT THE
GAS CYLINDER AFTER USE.
• READ THE INSTRUCTIONS BEFORE
USING THE APPLIANCE.
• PARTS SEALED BY THE
MANUFACTURER MUST NOT BE
ALTERED IN ANY WAY.
• THIS APPLIANCE IS ONLY TO BE
USED OUTDOORS.
Purchased from
Date purchased
Serial No.
NOTE: Sales docket must be kept as proof of purchase date.
FOR CUSTOMER REFERENCE
(Record and file in a safe place)
General Information
3
Safety
4
Outdoor Areas
5
Pre-Assembly
6
Assembly
7-10
Inspection
11
Assembly – General
12
Operation
13-15
Fault Finding
16
Maintenance
17-19
Parts Diagram / List
21-22
TABLE OF CONTENTS
The regulator and hose assembly supplied with the appliance are suitable
for use with bottled gas.
This regulator is adjusted to have an outlet pressure of 2.75 kPa for
connection to a gas cylinder only. The regulator and hose assembly supplied
with the appliance must be used. Replacement regulator and hose
assemblies must be those specified by the appliance manufacturer.
When connecting the hose and regulator assembly to the gas cylinder,
take care to avoid unnecessary twisting of the flexible hose. Also, take
care to avoid a loose connection with the gas cylinder. After the assembly
has been secured, turn on the gas and check for leaks by brushing a
soap and water solution over all visible and accessible gas line connections.
Include checking those connections which were made by your supplier.
The presence of bubbles will indicate a gas escape. DO NOT TEST FOR
GAS ESCAPES WITH AN OPEN FLAME. If you are unable to correct the
leak by tightening the connections, turn off the gas and contact your place
of purchase immediately.
Always ensure the appliance is kept away from flammable materials
and the gas cylinder clear of any heat source. When changing over from
an empty gas cylinder to a full one, make sure this procedure is carried
out in a flame free atmosphere.
Inspect the gas hose assembly when exchanging the gas cylinder,
or at least once a year, whichever is more frequent. If the ‘O-Ring’ or PVC
hose is cracked, cut, abraded or damaged in any way, the appliance must
not be operated. The complete assembly must be replaced if damaged
and when statutory conditions require it. Contact your place of purchase
if uncertain.
HOSE AND REGULATOR SAFETY
NEVER OPERATE THIS APPLIANCE
WITHOUT A REGULATOR.
This appliance is certified to AS 4557 by the Australian Gas Association.
Refer to data label on the appliance for certificate number.
This appliance must be used in accordance with the installation
requirements of your local gas supply authority, and the appropriate
installation standard AS5601.
GAS INSTALLATION CODES