Installation/ventilation requirements – Kleenmaid ICK66X User Manual
Page 7

7
INSTALLATION/VENTILATION
REQUIREMENTS
When installing an induction hob above an
underbench oven, cupboard or drawer unit,
the following ventilation requirements must
be observed:
• Heat Shield (heat resistent material, eg.
melamine timber veneer) is to be positioned
at least 50mm below hob.
• Cooktop must be isolated from under-
bench area. Heat Shield edges to be sealed
to surrounding surfaces
• A Vertical Division (heat resistent material,
eg. melamine timber veneer) is to be positio-
ned between the Heat Shield and the under-
side of the hob approximately 300mm from
back of cupboard. Length of Vertical Division
needs to be equal to
1
1 / INSTALLING YOUR APPLIANCE
•
•
width of Heat Shield. Vertical Division must .t
tightly and act as a barrier to air .owing back
towards the cooling fan in hob (as per dia-
gram).
• Ventilation holes must be drilled into side
of adjoining cupboards to allow fresh air
supply to cooktop.
•When installing into a granite worktop, drill
holes below worktop (as per diagram).
Insulation kit as shown in owners manual is
not required when installation is carried out
according to these speci.cations (this is not
supplied by Kleenmaid).
W
WA
AR
RN
NIIN
NG
G:: T
Th
he
e iin
nd
du
uc
cttiio
on
n c
co
oo
ok
ktto
op
p c
ca
an
nn
no
ott b
be
e
iin
ns
stta
alllle
ed
d a
ab
bo
ov
ve
e a
a ffrriid
dg
ge
e,, d
diis
sh
hw
wa
as
sh
he
err o
orr w
wa
as
s--
h
hiin
ng
g m
ma
ac
ch
hiin
ne
e..
IIn
nc
co
orrrre
ec
ctt iin
ns
stta
alllla
attiio
on
n o
orr ffa
aiillu
urre
e tto
o ffo
ollllo
ow
w
iin
ns
sttrru
uc
cttiio
on
ns
s m
ma
ay
y rre
es
su
ulltt iin
n p
prre
em
ma
attu
urre
e ffa
aiillu
urre
e
o
off c
co
oo
ok
ktto
op
p a
an
nd
d w
wiillll v
vo
oiid
d w
wa
arrrra
an
ntty
y..
300 mm
UNDERBENCH
AREA
Bottom Shelf
Kick Board
40 mm minimum
Induction Hob
Bench Top
Vertical Divider
Heat Shield
Drill 50 mm ventholes into
cabinet on both sides
aminated Worktop
4mm minimum
air outlet full
width of cooktop
Granite Worktop
Drill 5 mm vent
holes below the
worktop full
width of cooktop
OR
Induction cooktop
Granite Worktop
Underbench
50 mm
VENT HOLES
COOLING AIR FLOW
Air vents in hob to allow warm
air to be expelled from hob.
There must be a gap so air
flow is not restricted
COOLING FAN IN HOB
INDUCTION HOB
Vertical Divider - prevents air
flow cycle - ensures fresh
air enters cooling fan.
Copie de 99636771_EN_A.qxd 20/05/05 09:34 Page 7