INSTALLATION/VENTILATION
REQUIREMENTS

When installing an induction hob above an
underbench oven, cupboard or drawer unit,
the following ventilation requirements must
be observed:

• Heat Shield (heat resistent material, eg.
melamine timber veneer) is to be positioned
at least 50mm below hob.

• Cooktop must be isolated from under-
bench area. Heat Shield edges to be sealed
to surrounding surfaces

• A Vertical Division (heat resistent material,
eg. melamine timber veneer) is to be positio-
ned between the Heat Shield and the under-
side of the hob approximately 300mm from
back of cupboard. Length of Vertical Division
needs to be equal to

1

1 / INSTALLING YOUR APPLIANCE

width of Heat Shield. Vertical Division must .t
tightly and act as a barrier to air .owing back
towards the cooling fan in hob (as per dia-
gram).

• Ventilation holes must be drilled into side
of adjoining cupboards to allow fresh air
supply to cooktop.

•When installing into a granite worktop, drill
holes below worktop (as per diagram).
Insulation kit as shown in owners manual is
not required when installation is carried out
according to these speci.cations (this is not
supplied by Kleenmaid).

W

WA

AR

RN

NIIN

NG

G:: T

Th

he

e iin

nd

du

uc

cttiio

on

n c

co

oo

ok

ktto

op

p c

ca

an

nn

no

ott b

be

e

iin

ns

stta

alllle

ed

d a

ab

bo

ov

ve

e a

a ffrriid

dg

ge

e,, d

diis

sh

hw

wa

as

sh

he

err o

orr w

wa

as

s--

h

hiin

ng

g m

ma

ac

ch

hiin

ne

e..

IIn

nc

co

orrrre

ec

ctt iin

ns

stta

alllla

attiio

on

n o

orr ffa

aiillu

urre

e tto

o ffo

ollllo

ow

w

iin

ns

sttrru

uc

cttiio

on

ns

s m

ma

ay

y rre

es

su

ulltt iin

n p

prre

em

ma

attu

urre

e ffa

aiillu

urre

e

o

off c

co

oo

ok

ktto

op

p a

an

nd

d w

wiillll v

vo

oiid

d w

wa

arrrra

an

ntty

y..

300 mm

UNDERBENCH

AREA

Bottom Shelf

Kick Board

40 mm minimum

Induction Hob

Bench Top

Vertical Divider

Heat Shield

Drill 50 mm ventholes into

cabinet on both sides

aminated Worktop

4mm minimum

air outlet full

width of cooktop

Granite Worktop

Drill 5 mm vent

holes below the

worktop full

width of cooktop

OR

Induction cooktop

Granite Worktop

Underbench

50 mm

VENT HOLES

COOLING AIR FLOW

Air vents in hob to allow warm

air to be expelled from hob.

There must be a gap so air

flow is not restricted

COOLING FAN IN HOB

INDUCTION HOB

Vertical Divider - prevents air
flow cycle - ensures fresh
air enters cooling fan.

Copie de 99636771_EN_A.qxd 20/05/05 09:34 Page 7