Hook-up ick90x, 400v 3n, 240 v 3 – Kleenmaid ICK66X User Manual

Page 12: 240 v, 11 / installing your appliance

background image

9

1

1 / INSTALLING YOUR APPLIANCE

The appliance is to be installed in compliance
with the current Australian Electrical Stan-
dards.

The ICK90X has a total current draw of 48
amps.
Electrical Connections :

400V 3N

16 amps per phase 1.5 mm2 cable

220-240 V 3

32 amps per phase 2.5mm2 cable

220-240 V

- 40 amps per phase 6.0mm2 cable

- The cooktop can be wired with 2 sepa-

rate circuits.

16 amp circuit line 1
32 amp circuit lines 2 & 3

HOOK-UP ICK90X

2,5mm²

2,5mm²

2,5mm²

2,5mm²

32A

32A

32A

1,5mm²

16A

1,5mm²

16A

1,5mm²

16A

1,5mm²

16A

1,5mm²

1,5 mm²

16A

6mm²

40A

6mm²

40A

6mm²

1,5 mm²

16A

1,5 mm²

2,5 mm² 32A

2,5 mm² 32A

2,5 mm²

230 V3

1

2

3

4

5

L2

L3

L1

400V 3N

1

2

3

4

5

L2

N

L1

230V - 1 cable

1

2

3

4

5

L1

L3

N1

1

2

3

4

5

L

N

230V - 2 cables

N2

220-240 V

220-240 V

220-240 V 3

400V 3N

When power is first supplied to your hob, or
after an extended power outage, an indicator
light will appear on the control panel. It auto-
matically disappears after approximately 30
seconds, or as soon as any touch control on
the control panel is pressed. This display is
normal and, if needed, serves as an indication
to the after-sales service staff. In all cases, the
user of the hob should disregard it.