1 / INSTALLING YOUR APPLIANCE
The appliance is to be installed in compliance
with the current Australian Electrical Stan-
dards.
The ICK90X has a total current draw of 48
amps.
Electrical Connections :
400V 3N
16 amps per phase 1.5 mm2 cable
220-240 V 3
32 amps per phase 2.5mm2 cable
220-240 V
- 40 amps per phase 6.0mm2 cable
- The cooktop can be wired with 2 sepa-
rate circuits.
16 amp circuit line 1
32 amp circuit lines 2 & 3
HOOK-UP ICK90X
•
•
2,5mm²
2,5mm²
2,5mm²
2,5mm²
32A
32A
32A
1,5mm²
16A
1,5mm²
16A
1,5mm²
16A
1,5mm²
16A
1,5mm²
1,5 mm²
16A
6mm²
40A
6mm²
40A
6mm²
1,5 mm²
16A
1,5 mm²
2,5 mm² 32A
2,5 mm² 32A
2,5 mm²
230 V3
1
2
3
4
5
L2
L3
L1
400V 3N
1
2
3
4
5
L2
N
L1
230V - 1 cable
1
2
3
4
5
L1
L3
N1
1
2
3
4
5
L
N
230V - 2 cables
N2
220-240 V
220-240 V
220-240 V 3
400V 3N
When power is first supplied to your hob, or
after an extended power outage, an indicator
light will appear on the control panel. It auto-
matically disappears after approximately 30
seconds, or as soon as any touch control on
the control panel is pressed. This display is
normal and, if needed, serves as an indication
to the after-sales service staff. In all cases, the
user of the hob should disregard it.