Installation instructions, Ventilation of rooms, Gas connection – Kleenmaid CH611X User Manual
Page 11
![background image](https://www.manualsdir.com/files/792744/content/doc011.png)
10
INSTALLATION INSTRUCTIONS
VENTILATION OF ROOMS
The room in which this appliance is installed must be well ventilated by natural or mechanical means or
a combination of both to ensure correct combustion and the removal of spent air. The minimum
quantity of air for combustion will depend on the room volume, number of appliances and their total
power rating. The power rating of your appliance can be found by reference to the Rating Plate.
NOTE: The actual ventilation requirements must be determined by reference to the Statutory
Regulations in force.
GAS CONNECTION
Data Label – The Data Label is located on the underside of the appliance. A duplicate label is supplied
to adhere in an accessible area adjacent to the appliance. This appliance is suitable for Natural Gas
and propane Gas; ensure that the available gas supply matches the Data Label.
Test Point Pressure – The appliance is factory set for Natural gas. The test point pressure should be
adjusted to 1.00 kPa with the relevant burners operating at maximum flame (see Table Page 7).
Natural Gas – 1.00 kPa
Propane Gas – 2.75kPa
When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced
with the Test Point Assembly. A gas regulator suitable for a supply pressure of 2.75 kPa should be part
of the gas tank supply. Replace the old data plate with one, which is suitable for the type of gas for
which the appliance has been regulated.
The gas supply must be connected by use of the BSP Elbow, Seal and copper pipe and an isolation
tap fitted in an easily accessible position. For the location of the Gas Connection please refer to the
following table:
MODEL
Inlet Position
Inlet (mm)
from side
Inlet (mm)
from rear
CH611X CH611W
LHS Rear
50
40
CH611XFF CH611WFF
LHS Rear
50
40
CH612XFF
LHS Rear
50
39
CH711XFF
LHS Rear
105
40
CH911XFF
RHS Rear
55
40
CH912XFF
RHS Rear
60
39
CH913XFF
RHS Rear
60
39
CH915XFF CH915AFF
RHS Rear
40
40
CH920XFF
RHS Rear
60
45
CH1200XFF
RHS Rear
40
40