2 machine introduction, 3 positioning and location of the machine – Kemppi KMS 400 AS User Manual
Page 7

EN
2.2 Machine introduction
H12
H11
S11
X11
X12
X14
6,3A
X13
X15
01
F11
F11
Fuse for connection for control table
6.3 A delayed
X12
Earth connection
H11
Signal lamp
I/O
X14 , X15
Connection for control cable parallel
H12
Warning lamp for thermal protection
01
Inlet of mains cable
S11
Main switch
I/O
X11, X13
Welding connection
parallel
2.3 Positioning and location of the machine
Place the machine on a firm, dry and level surface. Where possible, do not allow dust or other
impurities to enter the machines cooling air flow. Preferably site the machine above floor level;
for example on a suitable carriage unit.
Notes for positioning the machine
• The surface inclination should not exceed 15 degrees.
• Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in
front of and behind the machine for cooling air to circulate.
• Protect the machine against heavy rain and direct sunshine.
NOTE!
The machine should not be operated in the rain as the protection class of the machine,
IP23S, allows for outside preserving and storage only.
NOTE!
Never aim metallic grinding spray/sparks towards the equipment.
5
© Kemppi Oy / 1515