Kemppi oy / 1515 – Kemppi SF 51 User Manual
Page 7
EN
2.2 Functions of SF 51 and SF 54 function panel
DYNAMICS
WIRE INCH
GAS TEST
weld
data
ARC FORCE
V
A
m/min
4T
SETUP
2T
U
MMA
MIG
MMA
PANEL
SF 51
W001318
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
1.
ON/OFF button
2.
a) Wire feed speed/welding current display
b) Selected SETUP entry display
3.
MIG dynamics/MMA Arc Force selection
4.
Selection of air/liquid cooled MIG gun
5.
Gas test
6.
Weld data: Show last used welding parameters in displays
7.
Wire inch
8.
a) Welding voltage display
b) Adjustable parameters display
9.
Selection of MIG/MMA process
10. a) Selection of switching logic: 2T/4T
b) Long press: Setting the basic parameters (SETUP)
11. a) Adjustment of wire feed speed
b) Adjustment of MMA current
c) Selection of SETUP parameter
12. a) Welding voltage adjustment
b) Adjustment of MIG dynamics
c) Adjustment of SETUP parameters
13. Manual control/remote control unit selection
5
© Kemppi Oy / 1515