Kemppi SF 51 User Manual
Page 10
EN
Remote Selection Button (13)
Remote control unit is connected to the device by pressing button 13. The wire feed speed
and welding voltage setting operations are performed via remote control. In this case,
potentiometers 11 and 12 of the panel are disconnected.
2.4 Panel SF 51 and SF 54 Setup parameters
Normal MIG welding Setup -parametres
Name of
parameter
Name on
display
Parameter
values
Factory
setting
Description
Pre Gas Time
PrG
0.0 – 9.9 s
0,0 s
Pre gas time in seconds
Post Gas Time
PoG
0.0 – 9.9 s
Aut
Post gas time in seconds or automatically according to
welding current (Aut)
Creep Start Level
CrE
10 – 170%
50 %
Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start
Start Power
StA
-9 ... +9
0
Strength of start pulse
Post Current Time
PoC
-9 ... +9
0
Post current
Arc Voltage
Ard
OFF, on
OFF
on: Display shows arc voltage
OFF: Display shows pole voltage
Cable Length
CAb
std, 5 – 80m std
Cable loss is calculated for optimal arc control and for the
Arc Voltage display
Common Setup -parameters for MIG processes
Name of
parameter
Name on
display
Parameter
values
Factory
setting
Description
Device Address
Add
3 or 6
3
Wire feeder bus address
Using features of
PMT Gun
Gun
OFF, on
on
on = PMT gun
OFF = other gun
Gas Guard
Connected
GG
no, YES
on
Implementation of gas guard
LongSystem Mode
LSY
OFF, on
OFF
on: Gives optimum welding characteristics with long
welding cables
Code Entry
Cod
---, Ent
---
Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)
Water Cooler
Coo
OFF, on
on
Enables water cooler
Wire Inch Stop
Inc
OFF, on
on
OFF = Stops wire inch in case arc does not ignite
on = Feeds wire as long as the welding gun start switch
is pressed.
FastMig SF 51, SF 54
8