Synergic Start Time
FSt
-9 ... +9
0
Start time in WiseRoot/WiseThin welding
Synergic Start
Voltage
FuL
-30 ... +30
0
Voltage level in the beginning of
WiseRoot/WiseThin welding
Start Power
StA
-9 ... +9
0
Strength of start pulse
(not in WiseRoot/WiseThin)
Post Current Time
PoC
-9 ... +9
0
Post current
Synergic MIG Unit
Unl
m/min, mm, A m/min
In 1-MIG and WiseRoot welding, the
parameter shown in left-hand display:
wire feed speed (m/min), sheet thickness
(mm) or average current (A)
Arc Voltage
Ard
OFF, on
OFF
on: Display shows arc voltage
OFF: Display shows pole voltage
(not in WiseRoot/WiseThin)
Cable Length
CAb
std, 5 – 80m
std
Cable loss is calculated for optimal arc
control and for the Arc Voltage display
(not in WiseRoot/WiseThin)
Common Setup -parameters for MIG processes
Name of parameter
Name on
display
Parameter
values
Factory
setting
Description
Device Address
Add
3 or 6
3
Wire feeder bus address
Using features of PMT
Gun
Gun
OFF, on
on
on = PMT gun
OFF = other gun
Gas Guard Connected
GG
no, YES
no
Implementation of gas guard
LongSystem Mode
LSY
OFF, on
OFF
on: Gives optimum welding characteristics
with long welding cables. Recommended
to be used when the cable length exceeds
40 m.
Code Entry
Cod
---, Ent
---
Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have
been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)
PIN Code Entry
PIn
---, PIn
---
Enters pin code for Panel Locking
Panel Locking
LoC
OFF, on
OFF
Enables panel locking
Water Cooler
Coo
OFF, on
on
Enables water cooler
Wire Inch Stop
Inc
OFF, on
on
OFF = Stops wire inch in case arc does not
ignite
on = Feeds wire as long as the welding
gun start switch is pressed.
Auto Wire Inch
AIn
OFF, on
on
SuperSnake Automatic Wire Inch
function. Wire Inch button runs the filler
wire from the wire feeder up to the
SuperSnake.
Demo Licence Time
dEt
3-h, 2-h, **’,
**’’, OFF
The remaining time for the WiseDemo
licence
(readable value only).
3-h = max. 3 hours left
2-h = max. 2 hours left
**’ = ** minutes left
**’’ = ** seconds left
OFF = Demo period has expired.