The table below lists the operation parameters and their possible values.

Name of

parameter

Name

displayed

Parameter

values

Factory

values

Description

Pre Gas Time

PrG

0.0 – 9.9 s

0.1 s

Pre-welding gas time in seconds

Post Gas Time

PoG

Aut, 0.1 – 32.0 s

Aut

Post-welding gas time in seconds or
automatically according to welding
current 1 s / 100 A (Aut)

Creep Start Level

CrE

10 – 170 %

50 %

Initial wire feeding speed as a
percentage of the pre-set value:
10% = slowed start
100% = no creep start
170% = rush start

Start power

StA

-9 ... +9

0

Strength of initial pulse

Post Current Time

PoC

-9 ... +9

0

Post-welding current time

Remote Switch

rS

2t4, Inc

2t4

Selection of wire feed device switch
operation

Calibration Menu

CAL

– – –, Ent

– – –

Wire feed speed calibration (see
instructions in sub-section 3.3.12)

LongSystem

Mode

LSy

on, OFF

OFF

Select ‘ON’ if you are using long (>40
m) connector cables

Restore Factory

Settings

FAC

OFF, PAn, All

OFF

Restore factory settings; exit the
menu by selecting ’All’

Water Cooler

COO

on, OFF

on

Enables water cooler

Wire Inc Stop

Inc

on, OFF

OFF

Safety function. Stops wire inch in
case arc does not ignite.

3.3.12 Calibration of the wire feed speed

When factory settings are used, the wire feed speed can be adjusted to between 4 and 100

without a unit of measurement. Only the LED symbol indicates that wire feed speed is the

parameter to be set.
The unit of the wire feed speed (m/min) is shown once the wire feed speed of the device has

been calibrated. To programmatically calibrate the wire feed speed:

1.

To prepare the welding equipment for calibrating, do the following:

• Connect the wire feeder to the power source with the control cable.

• Insert the filler wire in the gun, and run the wire out of the contact tip.

• Adjust the feeder wheels so that they are sufficiently tight.

• Start the power source and turn on the control panel with the start button, P1.

2.

Depress button P7 (SETUP) for at least five seconds. The set-up menu appears on the

display.

3.

Select the calibration menu (CAL) by rotating the left-hand knob, and then select the

value ’Enter’ (Ent) with the right-hand knob. Accept your selection by pressing button

P10 (REMOTE/LOCAL) briefly.

4.

Use the right-hand knob to select ‘m/min’ as the value of measure for the quantity to be

calibrated, and accept your selection by briefly pressing button P10 (REMOTE/LOCAL).

5.

Use the left-hand knob to set the lower calibration point to the desired value (e.g., 2.0 m/

min).

6.

Cut the filler wire at the contact tip end. Press the trigger, and let the wire run until it

stops automatically. If the wire is not moving when calibrating the lower point, increase

the wire feed speed value, e.g. to 4.0m/min.

7.

Measure the length of the loose wire end to an accuracy of 1 cm.

8.

Enter the measurement with the right-hand knob, and accept your selection by pressing

button P10 (REMOTE/LOCAL) briefly.

9.

Use the left-hand knob to set the higher calibration point to an appropriate value (e.g.,

FastMig KM 300, 400, 500