beautypg.com

Q-See QSTD5304 User Manual

Page 19

background image

QSTD5304 Digital Video Recorder User Manual

19

Notice: If continuous recording mode, manual record and alarm record are activated at

the same time. The alarm events can be found in Search by Event”, please refer to the
‘3.3.2 Search’ function in ‘3 Search by Event’.

9. COPY TO

Use this option to copy the settings of this channel to any other selected
channel.

SENSOR ALARM

Sensor alarm submenu is shown as Fig. 3.12. Every Sensor matches one or
more channels.

Fig 3.12 Sensor Alarm Configuration

1. HOLD TIME

This sets the continued recording time after an alarm is triggered. There are
two options: 1 minute and 2 minutes. It also determines the interval between
motion detection events. If the HOLD TIME is 1 minute, if new motion is
detected within this period it will be considered part of the previous event
instead of the start of a new event.

2. SENSOR

STEP1

Move the cursor to the "

SENSOR" option.

STEP2

Press "

Enter" key to switch the Sensor.

3. DETECTION

This is the switch of the sensor alarm. If you check "

DETECTION", DVR will

begin detecting. If you do not check it, the detection function is disabled.

4. TYPE

Press "

Enter" key to enter the sub-menu. There are two options: NO and NC.

‘NO’ means normal open. If ‘NO’ is chosen, the DVR will be triggered when
the alarm when the voltage drops.

‘NC’ means normal close. If ‘NC’ is chosen, the DVR will be triggered when
the alarm sends a high voltage charge.

5. TRIGGER RECORD

One channel can connect with one sensor. But one sensor can trigger one or
more channels.

STEP1

Move the cursor to "

TRIGGER RECORD" option.

STEP2

Select the channel you want that sensor to trigger.

STEP3

Press "

Enter" key to confirm the operation.