Insinger Commander 18-5 User Manual
Page 18
![background image](https://www.manualsdir.com/files/791075/content/doc018.png)
þ
NOTE:
Improper cleaning of the suction strainers
will cause the pumps to cavitate. This will
cause poor washing results.
CAUTION:
Level floats must be cleaned daily.
Build-up of grease and dirt will cause faulty operation
of the tank fill heating system.
7. Final rinse nozzles should be cleaned of matter
clogging the jet spray.
8. A door should be left open to allow drying of
interior surfaces.
6. Clean the tank level float with a plastic abrasive
pad (do not use steel wool).
CLEANING PROCEDURES (CONTINUED)
5. Clean suction strainers of build-up.
PART 3 OPERATION & CLEANING INSTRUCTIONS
þ
NOTE:
Upper & lower wash & rinse pipes are
not the same.
PRESSURE ADJUSTMENT
Pressure in the final rinse must be maintained at 20
± 2 psi. Adjustment of the pressure is made with
the adjusting screw on the pressure reducing valve.
If there are flow or pressure problems with the
pressure reducing valve, CAREFULLY remove the
strainer assembly and clean the strainer screen.
Be careful not to damage the Hex nut o-ring