beautypg.com

Insinger Commander 18-5 User Manual

Page 11

background image

Door Type Series DOC COM 1.0 06

www.insingermachine.com 800-344-4802

INSTALLATION INSTRUCTIONS
Commander 18-5 Series & CS Series

Placement
Carefully uncrate machine. Take caution not to
damage components which may be mounted on
the top or sides of the machine. Set unit in place
and adjust the feet to level the machine.

Fasten the tables to the load and unload side of the
machine. Most installations require fastening the
turn-down lip of the dish tables to the side of the
machine with flathead countersunk screws. The
table design should provide horizontal clearance of
30” for servicing.

Electrical Connections
Connect electrical lines sized for the correct
voltage, current and phase of the machine. These
should agree with the machine requirements
indicated on the nameplate and labels on the con-
trol panel.

A single-point electrical connection is provided for
the pumps, control circuit, and wash tank heater.

If an electric booster is provided, connect power
directly to the booster.

If the Insinger Self-Contained booster is provided
the machine comes standard with a Single-Point
Connection (to include the booster).

PART 2 INSTALLATION INSTRUCTIONS

CAUTION:

Connections must be made to a circuit breaker

or fused disconnect as provided by the

end-user and required by local codes.

A laminated wiring diagram is inside the control panel.

Model

208VAC/3È

230VAC/3È

380VAC/3È

460VAC/3È

220VAC/1È

18-5(C)
steam heat

6A

6A

6A

6A

15A

18-5(C)
electric heat

15A

15A

10A

10A

30A

18-5(C)
electric heat
Insinger SCB

60A

50A

35A

25A

100A

18-5H
steam heat

15A

10A

6A

6A

25A

18-5H
electric heat

25A

25A

15A

15A

45A

18-5H
electric heat
Insinger SCB

70A

60A

40A

30A

110A

Fuse Sizing Chart

9

This manual is related to the following products: