5 electrical connection of the encoder, Function terminal +u, And 1�5 mm – ifm electronic RN7003 User Manual
Page 8

CANopen encoder
8
Settings baud rate switch
Baud rate [kbits]
Baud rate switch
10
0
20
1
50
2
125
3
250
4
500
5
800
6
1000
7
400
8
Electrical connection of the encoder
4.5
NOTE
The unit must be connected by a qualified electrician�
Disconnect power before connecting the unit�
�
�
�
�
�
�
�
�
�
�
�
� � � �
�
�
�
�
�
�
� � � �
�
�
�
�
�
�
� � � �
�
�
�
�
Voltage supply U
1:
B
Function
Terminal
+U
B
(9���36 V DC)
+
0 V
-
The cable glands of the encoder must always be equipped with a shielded
power supply cable with a wire cross-section between 0�34 mm
2
and 1�5 mm
2
�
The permissible outer cable diameter is ø 8���ø 10 mm� Two screw terminals
with the required power supply terminals marked (+) and (-) are located inside
the cover�