Dip switch setup – Hypertherm SensorOHC User Manual
Page 21

Section 3: Installation and Set Up
17
DIP Switch Setup
SW1 SW2 SW3
Sensor Cable Length
on
on
on
cable length = 500 mm
off
on
on
cable length = 800 mm
on
off
on
cable length = 900 mm
off
off
on
cable length = 1000 mm *
on
on
off
cable length = 1200 mm
off
on
off
cable length = 1500 mm
SW4
In Position 0utput in Manual Mode
off
Normal - active output near height set point*
on
Forced active - always active in Manual Mode
SW5 SW6 Sensitivity & Loop Gain
off
off Sensitivity lowest - Lowest Gain Most Stable / use for high speed lifters ( > 3000 mm/min )*
on
off Sensitivity medium low
off
on Sensitivity medium high
on
on Sensitivity highest - Highest Gain Least Stable / use for low speed lifters ( < 750 mm/min )
SW7 SW8 Max Motor Current
off
off
Current lowest = 2.0 Amp 50W
on
off
Current medium low = 3.0 Amps 75W
off
on
Current medium high = 4.0 Amps 100W
on
on
Current highest = 6.0 Amps 150W*
* Indicates setting as shipped.
NOTE: The RJ45 connector under the calibration panel is not a network connection. It is a proprietary
connector and is for the use of authorized service personnel only.
DIP Switches