Operating data for high current cutting -10 – Hypertherm PAC500 Water Injection Plasma Cutting System User Manual
Page 41

4-10
PAC500
Instruction Manual
4
OPERATION
Operating Data for High Current Cutting
Material
Thickness
Inches
mm
Nozzle and
Swirl ring
Size
inches
Gas Type and
Flowmeter
Setting
%
Injection
Water Flow
Setting
%
Torch to
Work
Distance
Inches
mm
Arc
Voltage
Setting
Volts
Arc
Current
Setting
Amperes
Travel
Speed
ipm
mm/min
Stainless Steel
3
75
.250
70
100
1
25
215
900
15
380
4
100
.250
70
100
1
25
225
1000
10
255
5
130
.250
80
100
1
25
235
1000
6
150
Aluminum
3
75
.250
70
100
1
25
210
900
18
460
4
100
.250
70
100
1
25
210
900
12
305
5
130
.250
70
100
1
25
210
1000
8
200
6
150
.250
70
100
1
25
210
1000
7
180
Use the brass tapered nozzle retaining cap – part no. 020034
High Current Cutting is conventional cutting. It does not use the Water-Injection principle. The water sprayed from
the nozzle is for nozzle cooling purposes only. It does not constrict the arc.
Always remove the Water-Muffler and lower the water level in the Water-Table when operating in the High Current
Mode.
Caution:
Use of the Inductive IHS at high currents may damage the Inductive probes due to the high
amount of reflected heat and ejected metal during the pierce process.
Warning:
The plasma console is not vented for combustible gases. The optional ARGON/HYDROGEN
MANIFOLD part number 028057 is required when using Argon/Hydrogen gas mixtures.
Caution:
Never operate Water-Injection nozzles with Argon/Hydrogen gas mixtures.
Premixed
65% Argon
35% Hydrogen
Premixed
65% Argon
35% Hydrogen